Subscribe

ADJACENCIES · August 8, 2026

Types of Skylights: Fixed, Vented, Tubular, and Custom

Types of skylights compared: fixed, vented, tubular and custom, with 2026 costs, curb vs deck mounting by roof pitch, IRC glazing rules and model specs.

By The Roofing Brief Team. Last reviewed: October 2026.

The main types of skylights are fixed, vented (ventilating), tubular and custom or specialty units, and each of the first two can be curb-mounted or deck-mounted with glass or plastic glazing. HomeGuide’s skylight installation cost guide (updated August 29, 2025) puts installed prices at $1,500 to $4,000 for a fixed unit, $1,600 to $4,700 for a vented unit and $500 to $1,000 for a tubular sun tunnel. Pick the operation type first, then let roof pitch decide the mount: under 3:12, the International Residential Code wants a curb at least 4 inches high.

What are the main types of skylights?

By operation, skylights fall into four categories: fixed (sealed, never opens), vented or ventilating (opens for airflow), tubular (a small dome and reflective tube that pipes daylight into tight spaces), and custom or specialty units (domes, pyramids, and walk-on glass). In the VELUX 2025 residential catalog those map to the FS fixed, the VS manual, VSE electric and VSS solar “Fresh Air” vented units, and the TGR, TMR, TCR and TLR Sun Tunnel tubular models. Homeowners usually pick the operation type first, then decide on mounting and glazing.

Two other choices sit underneath that operation type and drive both price and leak risk: the mounting method (curb-mounted versus deck-mounted) and the glazing material (glass, acrylic, or polycarbonate). Mounting is not a separate “type” of skylight. A fixed skylight can be curb-mounted or deck-mounted, and so can a vented one: VELUX sells the fixed unit as the FS deck-mount (rated for 14 to 85 degrees, about 3:12 and steeper) and the FCM curb-mount (rated for 0 to 60 degrees, flat to 20:12), per its 2025 residential skylights catalog.

Types of skylights compared

The table compares the four operational types on how they work, the unit and installed price HomeGuide reports for each, what each suits, and relative leak risk. Price moves with unit size, roof material (HomeGuide notes metal and tile take more labor to cut than asphalt shingles), ceiling shaft length and whether an electrician is needed ($100 to $350 to connect an electric vented unit, per HomeGuide). For itemized pricing, see our skylight installation cost breakdown. To match a unit to your rough opening, use our VELUX skylight size chart.

Type How it works Unit only Installed Best for Relative leak risk Source
Fixed Sealed glazing that never opens; light only $150 to $800 $1,500 to $4,000 Stairwells, hallways, high ceilings, attics Lowest (no moving parts or seals) HomeGuide, Aug 2025
Vented, manual Opens by handle or control rod $300 to $1,200 $1,600 to $3,900 In-reach kitchen and bath openings Moderate (hinge, seal, and flashing wear) HomeGuide, Aug 2025
Vented, electric Wired motor, remote, rain sensor $1,100 to $1,600 $2,500 to $4,600 Out-of-reach openings with power nearby Moderate; rain sensor closes the sash HomeGuide, Aug 2025
Vented, solar Solar panel and battery run the motor; no wiring $1,100 to $2,000 $2,400 to $4,700 Out-of-reach openings with no wiring run Moderate; rain sensor closes the sash HomeGuide, Aug 2025
Tubular (sun tunnel) Roof dome feeds a reflective tube to a ceiling diffuser $150 to $500 $500 to $1,000 Closets, small baths, hallways with no attic-to-ceiling line of sight Low (15-1/4 in ceiling hole on a 14 in VELUX unit) HomeGuide; VELUX 2025 catalog
Custom / specialty Domes, pyramids, ridge glazing, or structural walk-on glass Quote only Quote only Architectural features, flat roofs, roof decks Higher on large penetrations; curb required under 3:12 VELUX 2025 catalog; IRC R308.6.8

Which type of skylight fits your roof and room?

Each row is a threshold you can check with a tape measure, a pitch gauge or the unit label. The rules come from the 2021 International Residential Code sections on skylights and from the published ranges in the VELUX and Solatube product data; confirm the exact model’s installation instructions, because the code lets the maker’s instructions override the curb rule.

If your situation is Choose Threshold or rule Source
Roof pitch below 3:12 (flat or low slope) Curb-mounted unit (VELUX FCM, VCM, VCE, VCS) or a curb-mount dome Curb at least 4 in above the roof plane unless the maker’s instructions say otherwise IRC R308.6.8
Pitched roof of 3:12 (14 degrees) to 85 degrees Deck-mounted unit (VELUX FS, VS, VSE, VSS) Rated 14 to 85 degrees; 14 standard sizes from A06 to S06 VELUX 2025 catalog
Kitchen, bath or hot upper room Vented, with a rain sensor if out of reach VSE and VSS include a rain sensor that closes the sash at the first sign of rain VELUX 2025 catalog
Room up to about 200 sq ft, no straight shaft 10 in tubular unit (Solatube 160 DS, VELUX TGR/TMR 010) Solatube rates the 160 DS for about 150 to 200 sq ft and about 20 ft of tube Solatube 160 DS
Room of 250 to 300 sq ft, or a tube run up to 30 ft 14 in tubular unit (Solatube 290 DS, VELUX TGR/TMR 014) Solatube rates the 290 DS for about 250 to 300 sq ft; VELUX lists 30 ft maximum for the rigid 014 Solatube 290 DS; VELUX catalog
Glass more than 12 ft above the floor, or a pane over 16 sq ft Laminated glass with a thicker interlayer PVB interlayer at least 0.030 in (0.015 in allowed only for panes of 16 sq ft or less, 12 ft or lower) IRC R308.6.2
Single-layer tempered or heat-strengthened glass Add a broken-glass retention screen, or switch to laminated Screen required under R308.6.3; laminated inboard panes need no screen under R308.6.5 IRC R308.6.3 to R308.6.5
Local rule bans domes on the roof Low-profile glass tubular unit (VELUX TLR) VELUX markets the TLR for places where ordinances prohibit domes; shingle roofs, 14 to 60 degrees VELUX 2025 catalog

Skylight types by model: what the spec sheets say

The same four types show up under different model codes at each maker. The table lists current VELUX and Solatube models with the pitch range (14 to 85 degrees for VELUX deck units), size range and maximum tube length each maker publishes, so you can match a type to a product number before asking for a quote.

Type Model Roof pitch range Sizes or coverage Notes Source
Fixed, deck-mount VELUX FS 14 to 85 degrees (3:12 and steeper) 14 sizes; A06 rough opening 14-1/2 x 45-3/4 in FS D26 and D06 sized to fit between roof trusses VELUX 2025 catalog
Vented, deck-mount VELUX VS (manual), VSE (electric), VSS (solar) 14 to 85 degrees Same rough openings as FS Insect screen included; VSE and VSS add a rain sensor VELUX 2025 catalog
Fixed or vented, curb-mount VELUX FCM, VCM, VCE, VCS 0 to 60 degrees (flat to 20:12) Outside curb from 17-1/2 x 33-1/2 in to 49-1/2 x 75-1/2 in Triple-pane glass is a special order on FCM only VELUX 2025 catalog
Tubular, 10 in VELUX TGR/TMR 010; Solatube 160 DS 14 to 60 degrees (VELUX) VELUX: 20 ft max rigid run; Solatube: about 150 to 200 sq ft VELUX rigid tubes carry a 20-year tube warranty VELUX catalog; Solatube
Tubular, 14 in VELUX TGR/TMR 014, TCR 014, TLR 014; Solatube 290 DS 14 to 60 degrees; TCR curb-mount 0 to 60 VELUX: 30 ft max rigid run; Solatube: about 250 to 300 sq ft Ceiling rough opening 15-1/4 in VELUX catalog; Solatube
Tubular, 22 in VELUX TGR 022 14 to 60 degrees 40 ft max rigid run; ceiling opening 22-3/4 in Flexible TGF 022 tops out at 12 ft VELUX 2025 catalog
Flat-roof specialty VELUX FXG SkyMax Flat and low-slope roofs Covers up to 35 sq ft, 10 ft at the longest side Made for flat and low-slope roofs VELUX 2025 catalog

Fixed skylights

A fixed skylight is a sealed glazed unit that does not open. With no hinge, motor, or weatherstripping to fail, it carries the lowest leak risk of the four types, and HomeGuide notes that fixed models “resist leaks better than ventilating models.” VELUX builds its FS fixed unit in 14 standard sizes, from the A06 (14-1/2 x 45-3/4 in rough opening) up to the S06 (44-1/4 x 45-3/4 in), and sizes the D26 and D06 to fit between roof trusses. Fixed units suit stairwells, hallways, vaulted living rooms, and attic conversions.

Because there are no moving parts, fixed skylights cost less than vented models: HomeGuide lists $150 to $800 for a fixed unit against $300 to $2,000 for a ventilating one, or $1,500 to $4,000 installed against $1,600 to $4,700. The trade-off is zero airflow: a fixed unit over a bathroom or kitchen does nothing for steam or cooking moisture, which can drive condensation on the glass in cold weather. Our guide to choosing a bathroom skylight covers venting and glazing.

Vented (ventilating) skylights

A vented skylight opens to let warm, humid air escape, which makes it the usual pick for kitchens, bathrooms, and rooms prone to moisture buildup. Opening the unit uses the stack effect: hot air rises and exits through the roof while cooler air is drawn in from lower windows. VELUX includes an insect screen on every venting unit in its 2025 catalog, and HomeGuide prices the installed vented range at $1,600 to $4,700 because of the operable sash, seals, and hardware.

Vented skylights are sometimes called roof windows, though the two terms are not identical. We break down the distinction in our guide on skylight vs roof window. In short, a true roof window such as the VELUX GGU center-pivot or GPU top-hinged unit is designed for occupied attic rooms, and VELUX’s catalog marks some sizes as satisfying most egress requirements, subject to local code officials. A vented skylight is a ceiling unit for light and air, not an exit.

Manual, electric, and solar venting

Vented skylights differ by how they open, and the mechanism changes both convenience and price:

  1. Manual ($1,600 to $3,900 installed, per HomeGuide): a turning handle for in-reach units or a control rod for out-of-reach ones. Lowest cost, but you have to remember to close it before rain.
  2. Electric ($2,500 to $4,600 installed): a wired motor with a remote, plus a rain sensor that closes the unit automatically. HomeGuide adds $100 to $350 for an electrician to connect it.
  3. Solar-powered ($2,400 to $4,700 installed): a rooftop panel runs the motor and charges a battery, so no wiring is needed. The federal credits that once covered some of these units ended for property placed in service after December 31, 2025, per the IRS energy efficient home improvement credit page and Public Law 119-21, even though HomeGuide’s cost guide still mentions a 26% to 30% credit. Our solar skylight guide covers the current rules.

For cost, daylight, and leak risk side by side, see fixed vs vented skylights compared head to head.

Tubular skylights (sun tunnels)

A tubular skylight, also called a sun tunnel, uses a small roof-mounted dome that channels daylight down a mirror-finished tube to a diffuser lens on the ceiling below. HomeGuide puts the installed cost at $500 to $1,000 and the unit at $150 to $500, the cheapest of the four types. VELUX sells tubes in 10, 14 and 22 inch sizes, and Solatube’s residential line uses a 10 inch tube (160 DS) and a 14 inch tube (290 DS).

Tubular units suit spaces a conventional skylight cannot reach: interior closets, small bathrooms, laundry rooms, and hallways where framing blocks a straight shaft. Tube length is the limit to check. VELUX lists a maximum recommended run of 20 ft for its 10 inch rigid tube, 30 ft for the 14 inch and 40 ft for the 22 inch, but only 8 to 12 ft for its flexible tubes, and rigid tubes carry a 20-year tube warranty. Add-ons in the VELUX catalog include an electric light kit, an energy kit, a daylight controller and a solar night light that fits inside the rigid tube.

Custom and specialty skylights

Custom and specialty skylights cover everything beyond a standard rectangle: domed and pyramid units for flat roofs, ridge and barrel-vault glazing that runs along a roof peak, and structural walk-on glass for roof decks and floors. These are made to order and priced by quote. The largest stock flat-roof unit in the VELUX residential catalog, the FXG SkyMax, covers up to 35 sq ft with a longest side of 10 ft; anything larger moves into VELUX’s architectural modular line or a custom fabricator.

Dome and pyramid shapes shed water and debris, which is why they are common on low-slope and flat roofs where a flat pane would pond. On any roof flatter than 3:12, IRC R308.6.8 requires a unit skylight to sit on a curb at least 4 inches above the roof plane unless the maker’s instructions say otherwise, and the VELUX TCR curb-mount dome is rated from 0 degrees. If your roof is flat or low-slope, start with our dedicated guide to flat roof skylights, which covers the curb and code details that matter most there.

Curb-mounted vs deck-mounted: the mounting question

Mounting is a separate decision from operation type, and it drives both cost and leak performance. A curb-mounted skylight sits on a raised frame (the curb) built above the roof deck; a deck-mounted skylight attaches directly to the deck and sits lower against the roofline. VELUX describes its curb unit as “built like a shoe box,” with the site-built curb as the box and the skylight as the lid. Any operation type can use either mount, though units on roofs below 3:12 are curb-mounted.

  • Curb-mounted: required on roofs below 3:12 under IRC R308.6.8 unless the maker says otherwise, and VELUX rates its FCM and VCM curb units from 0 to 60 degrees. HomeGuide notes curb units sit above the roof line and are easier to install.
  • Deck-mounted: sits flush with integrated factory flashing; VELUX rates its FS and VS deck units for 14 to 85 degrees. HomeGuide notes deck units take longer to install.

Whichever mount you choose, flashing decides whether the unit stays dry. VELUX ties its 10-year installation warranty on deck- and curb-mounted units to installation with VELUX flashing, which is the clearest signal that the flashing kit, not the glass, is where leaks start. Our skylight leak repair guide walks through the common failure points.

Glazing: glass, acrylic, and polycarbonate

Glazing is the see-through material, and the code limits what you can use. IRC R308.6.2 allows only laminated glass, fully tempered glass, heat-strengthened glass, wired glass and approved rigid plastics in skylights, and laminated glass needs a polyvinyl butyral interlayer of at least 0.015 inch for panes of 16 sq ft or less mounted 12 ft or lower, or 0.030 inch above that. VELUX’s Standard Safety Glass is laminated, double-paned and argon-filled. Acrylic and polycarbonate cost less and resist impact but can scratch or yellow. For a side-by-side of acrylic vs polycarbonate vs glass skylights, see our plastic skylights guide.

Beyond the material, count the glazing layers and read the label. The National Fenestration Rating Council label on a certified skylight lists U-factor, Solar Heat Gain Coefficient and visible transmittance; a lower U-factor means less heat loss, and a lower SHGC means less summer heat gain. Double glazing is the norm, and VELUX offers triple-pane glass only as a special order on its FCM curb-mount, which then cannot take a solar shade. For rooms that overheat or lose warmth through the roof, see our overview of energy efficient skylights for glazing and rating specifics.

How to choose the right type of skylight

Match the type to the room and roof in this order, and the rest of the spec follows:

  1. Does the room need airflow? Yes points to a vented unit; light-only points to fixed or tubular.
  2. Is there a straight line from roof to ceiling? No, or a room under about 200 sq ft, favors a 10 inch tubular unit; 250 to 300 sq ft favors a 14 inch tube.
  3. What is the roof slope? Below 3:12 needs a curb at least 4 inches high (IRC R308.6.8); 3:12 and steeper suits a deck-mounted unit for a flush seal.
  4. How much sun does the room already get? South- and west-facing rooms benefit most from a lower SHGC on the NFRC label.
  5. What is the budget and who installs it? HomeGuide lists $100 to $500 for the permit and inspection on a new skylight; compare models in our roundup of the best skylight brands and the VELUX skylight lineup.

Frequently asked questions

What are the three main types of skylights?

The three most commonly cited types are fixed, vented (ventilating), and tubular. Fixed skylights are sealed and provide light only, vented skylights open for airflow, and tubular skylights pipe daylight through a 10, 14 or 22 inch reflective tube into small or enclosed rooms. HomeGuide puts them at $1,500 to $4,000, $1,600 to $4,700 and $500 to $1,000 installed. Custom units such as domes and pyramids form a fourth category.

What is the difference between fixed and vented skylights?

A fixed skylight is permanently sealed and never opens, so it adds light but no ventilation and carries the lowest leak risk. A vented skylight opens by handle, control rod, motor, or solar actuator to release heat and humidity, which suits kitchens and bathrooms. HomeGuide lists fixed units at $150 to $800 and vented units at $300 to $2,000 before installation.

Which type of skylight is least likely to leak?

Fixed skylights leak the least because they have no hinge, seal, or motor to wear out, followed by tubular units with a small penetration (a 15-1/4 inch ceiling opening on a 14 inch VELUX tube). Across all types, flashing matters more than the glazing: VELUX ties its 10-year installation warranty to its own flashing kits, and roofs below 3:12 need a curb at least 4 inches high under IRC R308.6.8.

Are tubular skylights worth it?

Tubular skylights are worth it for small or enclosed rooms with no straight path for a conventional shaft, such as closets, interior bathrooms, and hallways. HomeGuide puts them at $500 to $1,000 installed, the cheapest daylighting option. Solatube rates its 10 inch 160 DS for about 150 to 200 sq ft of floor. They deliver less light than a full skylight and give no view of the sky.

What is the difference between curb-mounted and deck-mounted skylights?

A curb-mounted skylight sits on a raised frame above the roof deck and is required on roofs below 3:12 unless the maker says otherwise; VELUX curb units are rated from 0 to 60 degrees. A deck-mounted skylight attaches directly to the deck and sits flush with integrated flashing; VELUX deck units need at least 14 degrees, about 3:12. Mounting is separate from whether the unit is fixed or vented.

What glazing is best for a skylight?

Laminated insulated glass with a low-emissivity coating is the best all-round glazing, and it needs no protective screen under IRC R308.6.5. Single-layer tempered glass needs a broken-glass retention screen under R308.6.3. Acrylic and polycarbonate cost less and resist impact but can scratch or yellow over time. Compare the U-factor and SHGC on the NFRC label of the exact unit.