Subscribe

REPAIR · August 8, 2026

Roofing Cricket: What It Is and Where Your Roof Needs One

A roof cricket (roofing cricket or saddle) diverts water behind a chimney; IRC R1003.20 requires one over 30 in wide. Height table, framing and cost.

By The Roofing Brief Team. Last reviewed: October 2026.

A roof cricket, or roofing cricket, is the small peaked ridge, also called a saddle, that a roofer builds on the high side of a chimney or other wide roof penetration so water splits and runs around it instead of ponding against the back wall. It is a permanent diverter framed into the roof, not a flashing accessory, and on chimneys wider than 30 inches it is required by code under IRC R1003.20. Its minimum height runs from 1/8 of the chimney width on a 3:12 roof to 1/2 of the width on a 12:12 roof, and This Old House prices one at $700 to $1,300 (updated March 12, 2026).

What is a roofing cricket?

A roofing cricket is a ridged structure, shaped like a miniature gable roof, set on the up-slope side of a chimney, skylight, or curb to divert water around the obstruction. It rises from the main roof plane to a peak or ridge behind the penetration, so runoff and snowmelt split to both sides rather than collecting against a flat vertical face. The code uses cricket and saddle for the same part: IRC R903.2.2, “Crickets and saddles,” requires one on the ridge side of any chimney or penetration more than 30 inches wide measured perpendicular to the slope, covered in sheet metal or the same material as the roof.

The problem it solves is simple physics. Water flowing down a slope hits the back wall of a wide chimney, has nowhere to go, and pools. Standing water rots deck sheathing, degrades masonry mortar, and forces its way under flashing. A cricket gives that water two downhill paths off the corners of the chimney instead of one dead end, which is why IRC R1003.20 also requires the cricket-to-chimney joint to be flashed and counterflashed like any other roof-chimney intersection.

Cricket vs saddle vs diverter: the terms untangled

Cricket and saddle mean the same thing, but crews use several nearby terms for related parts, and mixing them up leads to the wrong repair. A cricket or saddle is a framed water diverter behind a wide penetration (IRC R903.2.2). A diverter or kickout flashing is a small bent metal piece, not a framed structure; IRC R903.2.1 requires one “to divert the water away from where the eave of a sloped roof intersects a vertical sidewall.” A valley and a curb are different parts entirely. The table sorts them out.

Term What it is Where it goes Framed or flashing
Cricket / saddle Peaked mini-roof that splits water around an obstruction Up-slope side of a chimney, skylight, or curb Framed structure
Diverter (kickout) flashing Bent metal that throws water away from a wall into the gutter Where a roof edge meets a sidewall Flashing piece
Valley Channel where two roof planes meet and drain together Internal angle between two slopes Roof plane detail
Curb Raised frame that lifts a skylight or unit above the roof Around skylights and rooftop equipment Framed base (often needs its own cricket)

The key distinction: a cricket is built up as its own little roof with its own slope, while a diverter is a single formed piece of metal that needs no framing and sits where IRC R903.2.1 calls for it, at the eave-to-sidewall corner. Our roof saddle install sequence covers the saddle wording in more depth, since some regions default to saddle over cricket.

Where a roof needs a cricket (it is not just chimneys)

Chimneys are the most common place for a cricket, but any wide obstruction that blocks downhill flow can need one. The code line is 30 inches: IRC R903.2.2 applies to “any chimney or penetration” wider than that across the slope, so a wide equipment curb or skylight curb is covered too, unless it is a unit skylight installed to the maker’s instructions. Skylights, HVAC curbs, dead valleys from additions, and wide walls all qualify depending on width and slope. Our explainer on the header curb covers when the upslope side of an equipment curb needs a cricket.

Location Why a cricket is needed Typical trigger
Chimney Wide masonry blocks runoff and holds water against the back wall Width over 30 in across the slope (code)
Skylight Frame dams water on the up-slope side, especially on low pitches Wide units or low slope where water lingers
HVAC or equipment curb Rooftop unit curb traps water and debris behind it Common on low-slope commercial roofs
Dead valley (addition or dormer) Two roofs meet and trap water with no clear outlet Where a new roof ties into an existing wall
Wide wall or parapet Long horizontal face collects sheeting water Roof-to-wall runs on low-slope roofs

On low-slope and flat roofs, crickets built from tapered insulation do the same job for drains and curbs. NRCA’s rule of thumb, restated in Professional Roofing (July/August 2026), is that cricket and saddle surfaces should be twice the slope of the adjacent roof field, so a 1/4 in per foot field gets a 1/2 in per foot cricket, and the cricket’s own valleys must also be sloped to drain.

When code requires a cricket: the 30-inch rule

The International Residential Code requires a cricket where a chimney measures more than 30 inches (762 mm) parallel to the ridgeline and does not intersect the ridge. That is the trigger in IRC Section R1003.20. Below 30 inches wide, or when the chimney straddles the ridge so water already splits, code does not force a cricket, though one can still help on low pitches.

The same section also requires that the intersection of the cricket and the chimney be flashed and counterflashed like a normal roof-to-chimney joint. The 2024 IRC keeps R1003.20 and its table unchanged, and the roof-assemblies chapter adds a second, broader rule in R903.2.2: a cricket on the ridge side of any chimney or penetration more than 30 inches wide measured perpendicular to the slope, with an exception for unit skylights installed to the maker’s instructions. Local amendments can differ, so confirm the adopted code edition with your jurisdiction. Our chimney flashing and counterflashing system guide shows how that joint is layered.

How big does a cricket have to be?

Cricket height is set by roof slope and chimney width, not guesswork. IRC Table R1003.20 gives the minimum cricket height (H) as a fraction of the chimney width parallel to the ridge (W). Steeper roofs need a taller cricket because water moves faster and needs a higher ridge to split cleanly; lower slopes need proportionally less height.

Roof slope Minimum cricket height (H) as a fraction of chimney width (W)
12:12 1/2 of W
8:12 1/3 of W
6:12 1/4 of W
4:12 1/6 of W
3:12 1/8 of W

To size a cricket from the table, follow these steps:

  1. Measure the chimney width parallel to the ridge. Call it W.
  2. If W is 30 inches or less and the chimney does not sit on the ridge, no cricket is required by code, though one may still be worthwhile on a low slope.
  3. If W is greater than 30 inches, a cricket is required under IRC R1003.20.
  4. Read the roof slope (for example 6:12).
  5. Multiply W by the fraction from Table R1003.20 to get the minimum cricket height H. A 40-inch-wide chimney on a 6:12 roof needs a cricket at least 1/4 of 40 inches, so 10 inches high.

Height is the code minimum, not a ceiling. Two other rules can push it higher: a shingled cricket must keep its own planes at 2:12 or steeper, because IRC R905.2.2 bars asphalt shingles below 2:12, and on low-slope roofs the NRCA rule of thumb calls for twice the field slope. For the framing geometry behind these numbers, see our cricket sizing, slope, and framing sequence.

Roof cricket height by chimney width: worked table

Minimum cricket height H for common chimney widths, from the fractions in IRC Table R1003.20. A 30 in chimney is shown for reference only; code requires the cricket once the width exceeds 30 in.

Chimney width W 3:12 (1/8 W) 4:12 (1/6 W) 6:12 (1/4 W) 8:12 (1/3 W) 12:12 (1/2 W) Source
30 in 3.75 in 5 in 7.5 in 10 in 15 in IRC Table R1003.20; heights are Roofing Brief arithmetic
36 in 4.5 in 6 in 9 in 12 in 18 in
40 in 5 in 6.7 in 10 in 13.3 in 20 in
48 in 6 in 8 in 12 in 16 in 24 in
60 in 7.5 in 10 in 15 in 20 in 30 in

Does your roof need a cricket? Decision table

If your roof has… Cricket required? Rule and threshold
A chimney over 30 in wide parallel to the ridge, below the ridge Yes IRC R1003.20; height from Table R1003.20
A chimney 30 in wide or less Not by code Optional; worth pricing if debris, snow or leaks collect behind it
A chimney that straddles the ridge No R1003.20 applies only where the chimney does not intersect the ridgeline
A curb, equipment base or other penetration over 30 in wide across the slope Yes IRC R903.2.2 covers “any chimney or penetration”
A unit skylight installed and flashed per the maker No R903.2.2 exception; VELUX deck-mount units are rated for 14 to 85 degree pitches
A shingled cricket whose planes would be under 2:12 Yes, but not in shingles Cover in sheet metal or membrane; IRC R905.2.2 bars asphalt shingles below 2:12
A low-slope or flat roof with a curb or drain Tapered-insulation cricket Twice the field slope (NRCA rule of thumb)

Roof cricket between two gables (dead valley)

A roof cricket between two gables solves the dead valley that forms when two gable roofs, or a gable and a wall, meet with no downhill outlet, often where an addition ties into the original house. IRC R903.2.1 requires flashing wherever there is a change in roof slope or direction, so the cricket and its flashing are one job. The cricket is framed as a small ridge across the flat spot so water splits into the two valleys on either side instead of sitting in the corner.

  1. Find the low point where water collects and measure the width of the flat area across the slope; a trap wider than 30 in falls under the same logic as IRC R903.2.2.
  2. Set the cricket ridge on the centerline of the flat area and slope each plane toward an open valley; on a shingled cricket each plane must be 2:12 or steeper (IRC R905.2.2), otherwise plan a metal or membrane cover.
  3. Frame with 2×4 or 2×6 members set on the existing deck, sheathe with plywood or OSB, then wrap the whole cricket and the wall or gable intersections in ASTM D1970 self-adhered membrane before any metal or shingles.
  4. Flash every change in slope or direction, as IRC R903.2.1 requires, and step-flash any sidewall with pieces at least 4 in by 4 in (IRC R905.2.8.3).

For skylights, a cricket or saddle is usually not needed when the skylight is a factory unit with the maker’s flashing kit: the R903.2.2 exception covers unit skylights installed to the manufacturer’s instructions, and VELUX’s deck-mount data sheet lists a 14 to 85 degree pitch range for the standard installation. A site-built curb over 30 in wide on a low pitch is the case that still gets a skylight cricket.

What a roofing cricket is made of

A steep-slope cricket is usually a small wood frame decked with plywood or OSB, wrapped in self-adhered membrane, then covered with metal flashing or the same shingles as the main roof, the two coverings IRC R903.2.2 allows. This Old House describes framing and sheathing crickets like the rest of the roof and then covering them completely with modified bitumen membrane folded up under the counterflashing. Small crickets on steep roofs tend to be metal-covered; larger ones use the field roofing material. The metal choices are aluminum, galvanized steel, or copper, in rising order of cost and lifespan.

  • Frame: dimensional lumber or plywood ridge and hip pieces set behind the chimney.
  • Deck: plywood or OSB sheathing over the frame.
  • Underlayment: self-adhered ice-and-water membrane (the type meeting ASTM D1970) run up the chimney and over the cricket seams first.
  • Surface: metal pan or field shingles, tied into step and counter flashing at the chimney.

Choose the surface by slope: if the cricket’s planes are under 2:12, shingles are not allowed under IRC R905.2.2, so the cover has to be sheet metal (aluminum, galvanized steel or copper) or membrane. Whatever the surface, the ASTM D1970 membrane goes down before the metal, because the membrane is the real waterproofing layer and the metal sheds the bulk of the flow.

How to tell if your roof already has a cricket

Most homeowners cannot say whether their chimney has a cricket, and a missing one is a slow leak waiting to happen. You can check from the ground, the attic, and after a rain without climbing on the roof. Start with the number that matters: measure the chimney chase in the attic or the masonry from a ladder, parallel to the ridge. Over 30 in and below the ridge, a cricket is required under IRC R1003.20.

  1. Stand back on the up-slope side of the chimney and look for a small triangular ridge rising off the roof against the back of the masonry; on a 40 in chimney and a 6:12 roof it should stand at least 10 in tall.
  2. Look for a metal or shingled surface that splits to both sides rather than a flat gap packed with leaves.
  3. From the attic, check for short framing members behind the chimney and for water stains on the sheathing there.
  4. Inspect the ceiling and wall directly below the chimney chase for old or fresh staining.
  5. After heavy rain, watch whether water sheets straight into the back wall of the chimney or divides and runs off the corners.

If the back of the chimney is a flat shelf that collects debris, there is probably no cricket. On a chimney over 30 in wide that is a code deficiency under IRC R1003.20, and the cheapest time to fix it is the next reroof, when the deck is already open.

Signs a cricket is missing or failing

A cricket problem shows up as water damage traced to the up-slope side of a chimney or skylight. The failure is rarely the cricket structure itself; it is usually the flashing and counterflashing joint that IRC R1003.20 requires where the cricket meets the masonry, or the absence of any cricket on a chimney over 30 in wide. Watch for these signs:

  • Dark staining, moss, or streaking on the shingles directly behind (up-slope of) the chimney.
  • A recurring interior leak near the chimney chase that returns after each storm.
  • Granule loss fanning out behind the chimney where trapped water sits.
  • Rust, open seams, or lifted edges on the cricket metal.
  • Sealant smeared over a flashing gap instead of metal cut into a masonry reglet.

Because the leak and the flashing usually fail together, a proper fix pairs the cricket with new step and counter flashing; This Old House lists chimney flashing repair at $200 to $300 on its own. See the failure modes in our guide to the signs of failed chimney flashing.

What a cricket costs and who builds it

This Old House prices a chimney cricket at $700 to $1,300 in its chimney repair cost guide (updated March 12, 2026). Where a quote lands in or above that range follows chimney width, roof pitch and the flashing metal: a 48 in chimney on a 12:12 roof needs a 24 in tall cricket, three times the 8 in cricket the same chimney needs at 4:12.

Cost driver Effect on price Source
Chimney width (W) Wider chimneys need a larger cricket and more material; height scales with W IRC Table R1003.20
Roof pitch Steeper roofs raise both the required height (1/8 W at 3:12 up to 1/2 W at 12:12) and the labor to work safely IRC Table R1003.20
Flashing metal Aluminum is cheapest; galvanized mid-range; copper the most expensive Retail metal pricing
New build vs retrofit Framing during a reroof costs less than cutting one into an intact roof Labor scope
Baseline cricket, framed and flashed $700 to $1,300 This Old House, Mar. 12, 2026
Chimney flashing repair alone $200 to $300 This Old House, Mar. 12, 2026

The work is roofing carpentry plus flashing, so a licensed roofer, not a chimney sweep, typically builds it, often during a reroof when the deck is open and the $700 to $1,300 This Old House range applies without tear-out. For a full 2026 cost breakdown and the ten-step build, see our step-by-step chimney cricket build and install cost.

Frequently asked questions

Is a roofing cricket the same as a saddle?

Yes. Cricket and saddle are two names for the same part: a small peaked ridge built on the up-slope side of a chimney or wide penetration to divert water around it. Regions and trades favor one term over the other, but they describe the identical framed structure, and the IRC names both in Section R903.2.2, “Crickets and saddles.”

Does every chimney need a cricket?

No. Under IRC R1003.20, a cricket is required only where the chimney measures more than 30 inches parallel to the ridge and does not intersect the ridgeline. Narrow chimneys and those that straddle the ridge already shed water to both sides, so code does not require one. On low-slope roofs, adding a cricket to a narrower chimney can still reduce ponding and is often worthwhile.

What slope should a roofing cricket be?

A cricket’s height is set by IRC Table R1003.20, which gives minimum height as a fraction of chimney width based on roof slope: 1/2 of the width at 12:12, 1/4 at 6:12, and 1/6 at 4:12, among other values. Steeper roofs need a taller cricket. On flat and low-slope roofs, NRCA’s rule of thumb is a cricket at twice the slope of the roof field.

Do skylights need a cricket?

Usually not. IRC R903.2.2 exempts unit skylights installed and flashed to the manufacturer’s instructions, and VELUX rates its deck-mount skylights for roof pitches of 14 to 85 degrees. A site-built skylight curb more than 30 inches wide across the slope, especially on a low pitch, is the case that still gets a cricket.

Can a cricket be added to an existing roof?

Yes, though it is easier during a reroof. Adding a cricket to an intact roof means cutting back shingles behind the chimney, framing and decking the cricket, running new ice-and-water membrane, and installing fresh step and counter flashing. Because the flashing joint has to be rebuilt either way, a retrofit is usually paired with a reroof or chimney flashing repair; This Old House prices the cricket itself at $700 to $1,300.

What happens if a wide chimney has no cricket?

Water piles up against the back wall of the chimney and works under the flashing. Over time that causes deck rot behind the chimney, mortar and masonry decay, and recurring interior leaks near the chase. Debris also collects in the flat trap, holding moisture longer. On a chimney wider than 30 inches, a missing cricket is both a code deficiency and a predictable long-term leak.